Description
Laparoscopic Anderson–Hynes pyeloplasty requires careful assessment, preservation of blood supply and precise reconstruction. This 60-second video highlights six avoidable errors involving diagnosis, crossing vessels, tissue handling, anastomotic alignment, suturing, stent placement and follow-up.
Hydronephrosis alone does not establish functional obstruction. Treatment planning should consider symptoms, anatomical findings, drainage and renal function.
Stenting and postoperative assessment should follow the individual operative plan. Follow-up must include a removal plan for any stent and assessment of recovery. Some collecting-system dilatation can persist despite improved drainage.
For surgical education—a focused safety reminder rather than a complete operative protocol.